EVD Tower 6KVA
High Reliability:
Online double conversion, 0.99 input power factor, wide voltage (110-286Vac) & frequency range.
- Recommended for Data Centers, Local Area Network (LAN ), Electro-medical, Industry processes, Virtual servers, Pellet stoves, Thermo-fireplaces, Boilers for home heating
- Intelligent slot for SNMP card o Dry Contact
- Compatibility with generating set
- Battery charging system managed by microprocessor
- Frequency converter mode
| MODEL |
EVD6T-MM |
EVD10T-MM |
|
| Capacity |
6000VA/ 5400W |
10000VA/ 9000W |
|
| INPUT | |||
| Nominal voltage |
208/220/230/240Vac |
||
| Input voltage range |
110~286Vac |
||
| Frequency range |
40~70Hz (50/60Hz Auto-Sensing) |
||
| Power factor |
≥0.99 |
||
|
Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) |
|||
| Bypass voltage range |
240V:+15% (Optional+10%) |
||
|
Min.voltage:-45% (Optional-20%,-30%) |
|||
| OUTPUT | |||
| Output voltage |
208/220/230/240Vac |
||
| Power factor |
0.9 |
||
| Voltage regulation |
±1% |
||
| Output frequency | Line Mode |
±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional) |
|
| Bat. Mode |
(50/60±0.1%)Hz |
||
| Crest factor |
3:01 |
||
| Harmonic distortion (THDv) |
≤2% Linear load |
||
|
≤5% Non linear load |
|||
| Transfer time | AC mode to Bat.Mode |
0ms |
|
| Inverter to Bypass |
0ms |
||
| Output waveform |
Pure Sinewave |
||
| Overload | Line Mode |
Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min; >150% turn to bypass mode immediately |
|
| Bypass Mode |
40A (Breaker) |
63A (Breaker) |
|
| fficiency |
94% |
||
| BATTERY | |||
| Battery voltage |
(12V/9Ah) 16/18/20 Pcs . Can be set 20 pcs no power derating |
||
| Capacity (Standard unit) |
9Ah/12V (7Ah/12V optional) |
||
| Typical recharging time |
6~8 hours (to 90% of full capacity) |
||
| Charging current |
1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity) |
||
| INDICATORS | |||
| LED display |
Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
||
| LCD display |
Input voltage,Input frequency,Output voltage,Output frequency,Load percentage, |
||
|
Battery voltage,Inner temperature& Remaining battery backup time |
|||
| ALARM | |||
| Battery mode |
Beeping every 4 seconds |
||
| Battery low |
Beeping every second |
||
| Overload |
Beeping twice every second |
||
| Fault |
Continously beeping |
||
| PHYSICAL | |||
| Dimension W x D×H (mm) |
191 x 460 x 720 |
||
| Net weight (kg) |
69 |
71 |
|
| ENVIRONMENT | |||
| Operating temperature |
0℃~40℃ |
||
| Storage temperature |
-25℃~55℃ |
||
| Humidity range |
20~95%RH @ 0~40℃ (Non condensing) |
||
| Altitude |
<1500m,derating required when>1500m |
||
| Noise level |
<55db at 1 Meter |
<58db at 1 Meter |
|
| STANDARDS | |||
| Safety |
IEC/EN62040-1,IEC/EN62477-1 |
||
| EMC |
IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
||